MiVoice Business SNMP Configuration For MiVB Before 9.0
SNMP access must be enabled for Mitel Performance Analytics to collect system alarms and memory utilization data and to acknowledge Emergency Response (ER) alarms. To configure SNMP for MiVoice Business prior to v9.0, do the following:
1. Log into the MiVoice Business System Administration Tool as super user or admin.
2. Navigate to System Properties > System Administration and open the SNMP Configuration form. Confirm the following:
Enable SNMP Agent: Set to Yes
Read-Only Community string: If ER alarms do not need to be monitored, ensure this string is the same as that configured in Mitel Performance Analytics. The default is public.
Read/Write Community string: If ER alarms need to be monitored, ensure this string is the same as that configured in Mitel Performance Analytics. The default is private.
Accept Requests from All Managers: Can be set to Yes or No. If set to No, ensure the Accept Requests from the following Managers panel contains the Probe IP address. For Mitel Performance Analytics on premise installation, the Probe IP address is the IP address of the Mitel Performance Analytics server.
3. Go to the SNMP Trap Forwarding form and add the Mitel Performance Analytics Probe IP address as a member in the Trap Forwarding Attributes table. Ensure that the SNMP trap community string is the same as the string used for SNMP reads and set the ER Notification option to Yes.
Note: Only one entry per MiVoice Business can have the ER Notification options set to yes. If you use a different tool to collect emergency response notification, do not use this option for Mitel Performance Analytics.