Mitel SIP DECT OMM Alarms

The following SIP DECT OMM alarms appear on the Mitel Performance Analytics Alarms panel and the Alarm Analytics pane when there is a problem between redundant SIP DECT OMM devices. Additional device alarms are possible.

 

Alarm Message Severity Cause

Failover occurred. New status is: Primary/Standby

Minor

When a failover status occurs between two redundant OMM devices.

[Health/standby] - Connection broken

Major

The connection between redundant OMM devices is broken.

[Health/rfp] - Wrong standby configuration

Major

Where there is a mismatch between OMM device configuration. For example, OMM (a) is configured with OMM (b) as a redundant standby device, but OMM (b) is configured as a standalone device.

Failed to connect to the expected Primary OMM

Critical

Failed to connect to the expected Primary OMM

Disk Swap Space Usage threshold exceeded.

Depends on the configured threshold values

The configured disk swap space usage threshold has been exceeded. See "Threshold Configuration".