Mitel SIP DECT OMM Alarms
The following SIP DECT OMM alarms appear on the Mitel Performance Analytics Alarms panel and the Alarm Analytics pane when there is a problem between redundant SIP DECT OMM devices. Additional device alarms are possible.
Alarm Message | Severity | Cause |
---|---|---|
Failover occurred. New status is: Primary/Standby |
Minor |
When a failover status occurs between two redundant OMM devices. |
[Health/standby] - Connection broken |
Major |
The connection between redundant OMM devices is broken. |
[Health/rfp] - Wrong standby configuration |
Major |
Where there is a mismatch between OMM device configuration. For example, OMM (a) is configured with OMM (b) as a redundant standby device, but OMM (b) is configured as a standalone device. |
Failed to connect to the expected Primary OMM |
Critical |
Failed to connect to the expected Primary OMM |
Disk Swap Space Usage threshold exceeded. |
Depends on the configured threshold values |
The configured disk swap space usage threshold has been exceeded. See "Threshold Configuration". |